		Mauna Loa Solar Observatory Observer's Log 
-----------------------------------------------------------------------------
	Tue Aug 17 16:28:51 GMT 1999
Year: 99  Doy: 229
Observer: yasukawa
WEATHER COMMENT: Tue Aug 17 16:29:33 GMT 1999
Cool, clear, light south wind.
Tue Aug 17 16:29:51 GMT 1999	CHIP	 Startup--Initializing new tape
Tue Aug 17 16:38:14 GMT 1999    MKIV    Start Patrol
Tue Aug 17 16:38:23 GMT 1999	PICS	 Start Patrol
Tue Aug 17 16:38:23 GMT 1999	PICS	 Start Patrol
**LOW-L PROBLEM**: Tue Aug 17 16:43:52 GMT 1999
L00619 was found popped out of drive #1 this morning, around 2/3 full.
Reset time and date and restarted lowl program, data writing to L00620
in drive #0.  Cleaned drive #1 and loaded L00621.
**MKIV PROBLEM**: Tue Aug 17 16:46:19 GMT 1999
KCC display is streaky (radial streaks).  Not sure whether this is a 
result of new program picked up this morning or the "usual" streaks
we see when the KCC flakes out.  Stopping Patrol gracefully and parking
barrel with End Day then resetting the KCC.
Tue Aug 17 17:00:06 GMT 1999    MKIV    Start Patrol
**PICS PROBLEM**: Tue Aug 17 17:01:23 GMT 1999
YCC monitor is off, stopping PICS and CHIP and resetting YCC after calibration
and hourly transfers pau.
Tue Aug 17 17:02:51 GMT 1999	CHIP	 Bias
Tue Aug 17 17:03:45 GMT 1999	CHIP	 End Bias
Tue Aug 17 17:04:03 GMT 1999	CHIP	 Water
**MKIV PROBLEM**: Tue Aug 17 17:04:40 GMT 1999
Streaking went away with the KCC reset.
Tue Aug 17 17:04:52 GMT 1999	CHIP	 End Water
Tue Aug 17 17:06:52 GMT 1999	PICS	 End Patrol
Tue Aug 17 17:08:28 GMT 1999	CHIP	 CHIP End Patrol
Tue Aug 17 17:10:46 GMT 1999	CHIP	 CHIP Start Patrol
Tue Aug 17 17:12:26 GMT 1999	PICS	 Start Patrol
**PICS PROBLEM**: Tue Aug 17 17:13:34 GMT 1999
Problem initializing.  Cancelled WaitRepl.  Ended Patrol attempt,
restarting Patrol.
Tue Aug 17 17:14:35 GMT 1999	PICS	 End Patrol
Tue Aug 17 17:15:38 GMT 1999	PICS	 Start Patrol
**MKIV PROBLEM**: Tue Aug 17 17:19:14 GMT 1999
Display acting like there is high sky polarization at 1.0 and 0.5
gain setting.  There are "bright" outer wedges at the east and west
quadrants.  This is possibly a result of the program changes made by
David overnight???
**MKIV PROBLEM**: Tue Aug 17 17:45:23 GMT 1999
Bright wedges might have actually been bad sky??? They were gone in 
last few scans at 0.5 gain.  MKIII was dark in that region until
last few scans too.
Tue Aug 17 17:46:56 GMT 1999    MKIV    Start Correct
Tue Aug 17 17:46:57 GMT 1999
Running a MKIV correct.
Tue Aug 17 17:48:11 GMT 1999    MKIV    End Correct
Tue Aug 17 17:48:23 GMT 1999    MKIV    Start Cal
Tue Aug 17 18:01:50 GMT 1999	CHIP	 Bias
Tue Aug 17 18:02:04 GMT 1999	PICS	 Flat
Tue Aug 17 18:02:43 GMT 1999	CHIP	 End Bias
Tue Aug 17 18:02:57 GMT 1999	CHIP	 Water
Tue Aug 17 18:03:38 GMT 1999	CHIP	 End Water
Tue Aug 17 18:04:36 GMT 1999	PICS	 End Flat
MKIV COMMENT: Tue Aug 17 18:15:45 GMT 1999
Calibrations pau.
MKIV COMMENT: Tue Aug 17 18:32:12 GMT 1999
Re-doing calibration.  First attempt was short for some reason according
to Alice.
**MKIV PROBLEM**: Tue Aug 17 18:56:28 GMT 1999
Changes made by David did not get rid of noise.  Stopping MKIII/IV
and opening up MKIV to remove video cable from back of camera to see
if that is somehow injecting noise into the system.
**MKIV PROBLEM**: Tue Aug 17 19:01:36 GMT 1999
OK, video cable is unplugged, BNC is taped up and secured so it won't
touch any part of the camera during this test.
Tue Aug 17 19:02:24 GMT 1999    MKIV    Start Patrol
Tue Aug 17 19:02:49 GMT 1999	CHIP	 End Bias
Tue Aug 17 19:02:58 GMT 1999	CHIP	 Water
Tue Aug 17 19:03:04 GMT 1999	PICS	 polarization_calibration
Tue Aug 17 19:03:41 GMT 1999	CHIP	 End Water
COMMENT: Tue Aug 17 19:27:46 GMT 1999
Stopping to reconfigure dome shutter.
Tue Aug 17 19:29:00 GMT 1999	PICS	 End Patrol
Tue Aug 17 19:30:21 GMT 1999	CHIP	 CHIP End Patrol
Tue Aug 17 19:32:46 GMT 1999    MKIV    End Patrol
Tue Aug 17 19:40:31 GMT 1999    MKIV    Start Patrol
Tue Aug 17 19:40:56 GMT 1999	PICS	 Start Patrol
Tue Aug 17 19:40:56 GMT 1999	PICS	 Start Patrol
Tue Aug 17 20:02:48 GMT 1999	CHIP	 Gain
Tue Aug 17 20:07:17 GMT 1999	CHIP	 End Gain
Tue Aug 17 20:07:32 GMT 1999	CHIP	 Bias
Tue Aug 17 20:08:28 GMT 1999	CHIP	 End Bias
Tue Aug 17 20:08:37 GMT 1999	CHIP	 Water
Tue Aug 17 20:09:12 GMT 1999	CHIP	 End Water
Tue Aug 17 21:00:48 GMT 1999	CHIP	 Bias
Tue Aug 17 21:01:38 GMT 1999	CHIP	 End Bias
Tue Aug 17 21:01:57 GMT 1999	CHIP	 Water
Tue Aug 17 21:02:48 GMT 1999	CHIP	 End Water
MKIV COMMENT: Tue Aug 17 21:13:34 GMT 1999
Stopping to reconnect video cable to camera.  Noise still present.
Tue Aug 17 21:16:41 GMT 1999    MKIV    Start Patrol
**MKIV PROBLEM**: Tue Aug 17 21:16:48 GMT 1999
Checked for discrepancies between jumper settings on new transformation
board and the old one.  Emailed list of discrepancies to David for
analysis--there were discrepancies and these were purposely made
when we changed transformation boards.
**MKIV PROBLEM**: Tue Aug 17 21:36:36 GMT 1999
Swapped jumpers from 320 to 322 on the transformation board.
**MKIV PROBLEM**: Tue Aug 17 21:44:11 GMT 1999
Display disappeared with that jumper change.
**MKIV PROBLEM**: Tue Aug 17 21:45:37 GMT 1999
Restoring jumpers on 320 and 322.
**MKIV PROBLEM**: Tue Aug 17 21:46:44 GMT 1999
swapping switch settings on U2 and U3 to old settings.
**MKIV PROBLEM**: Tue Aug 17 21:49:05 GMT 1999
OK, done.
**MKIV PROBLEM**: Tue Aug 17 21:54:40 GMT 1999
I do not see any change in the display noise with that swap.
Resetting U2 and U3 switch settings back to where they were and
configuring straps on 408, 409, and 410 to the old configuration.
**MKIV PROBLEM**: Tue Aug 17 21:58:29 GMT 1999
OK, done.  Display currently showing circular streaks.  Let's see what happens
when the scan resets.
Tue Aug 17 22:00:48 GMT 1999	CHIP	 Bias
Tue Aug 17 22:01:44 GMT 1999	CHIP	 End Bias
Tue Aug 17 22:02:07 GMT 1999	CHIP	 Water
**MKIV PROBLEM**: Tue Aug 17 22:03:10 GMT 1999
Nope, streaks did not go away.  I will restore straps one at a time.
**MKIV PROBLEM**: Tue Aug 17 22:05:04 GMT 1999
Removed 410 briefly and coronal display returned.  Put 409 back and display
remained the same.  strapped 410 again briefly (with 409 strapped) and 
streaks reappeared.  Strapped 408 alone and image appeared.  Strapped 410
again, with 408 and streaks recurred.  Removed strap from 410 and strapped 409,
the original configuration for the new board. display is back.
None of those swaps appeared to improve on the S/N in the displayed image.
Tue Aug 17 22:19:04 GMT 1999	PICS	 End Patrol
Tue Aug 17 22:21:22 GMT 1999	CHIP	 CHIP End Patrol
Tue Aug 17 22:22:22 GMT 1999	CHIP	 ending tape
COMMENT: Tue Aug 17 22:24:33 GMT 1999
Tapes:

MKIV:  99-229
PICS:  P01520
CHIP:  C00897
LOWL:  L00620 in drive #0
Tue Aug 17 22:29:12 GMT 1999 
	MkIII	
 
16_38.rawmk3   17_59.rawmk3   19_25.rawmk3   20_39.rawmk3   21_46.rawmk3
16_41.rawmk3   18_07.rawmk3   19_29.rawmk3   20_43.rawmk3   21_50.rawmk3
16_45.rawmk3   18_11.rawmk3   19_40.rawmk3   20_46.rawmk3   21_54.rawmk3
16_49.rawmk3   18_15.rawmk3   19_44.rawmk3   20_50.rawmk3   21_58.rawmk3
17_00.rawmk3   18_19.rawmk3   19_48.rawmk3   20_54.rawmk3   22_01.rawmk3
17_04.rawmk3   18_23.rawmk3   19_52.rawmk3   20_58.rawmk3   22_05.rawmk3
17_08.rawmk3   18_26.rawmk3   19_56.rawmk3   21_02.rawmk3   22_09.rawmk3
17_12.rawmk3   18_30.rawmk3   20_00.rawmk3   21_05.rawmk3   22_13.rawmk3
17_16.rawmk3   18_38.rawmk3   20_04.rawmk3   21_09.rawmk3   22_17.rawmk3
17_20.rawmk3   18_46.rawmk3   20_08.rawmk3   21_16.rawmk3   22_20.rawmk3
17_23.rawmk3   18_54.rawmk3   20_12.rawmk3   21_20.rawmk3   c17_48.rawmk3
17_27.rawmk3   19_02.rawmk3   20_16.rawmk3   21_24.rawmk3   c17_55.rawmk3
17_31.rawmk3   19_06.rawmk3   20_19.rawmk3   21_28.rawmk3   c18_03.rawmk3
17_35.rawmk3   19_09.rawmk3   20_23.rawmk3   21_31.rawmk3   c18_34.rawmk3
17_38.rawmk3   19_13.rawmk3   20_27.rawmk3   21_35.rawmk3   c18_42.rawmk3
17_42.rawmk3   19_17.rawmk3   20_31.rawmk3   21_39.rawmk3   c18_50.rawmk3
17_52.rawmk3   19_21.rawmk3   20_35.rawmk3   21_42.rawmk3