Mauna Loa Solar Observatory Observer's Log ----------------------------------------------------------------------------- Wed Mar 9 17:33:42 GMT 1994 Year: 94 Doy: 068 Observer: yasukawa COMMENT: Wed Mar 9 17:34:32 GMT 1994 Clear, cool-- 9.8 degrees C., brisk southeasst wind. DPMON COMMENT: Wed Mar 9 17:36:05 GMT 1994 Daystar temp left at 8.3 yesterday. Will start there for now. Wed Mar 9 17:37:45 GMT 1994: Patrol Start MKIII COMMENT: Wed Mar 9 17:38:51 GMT 1994 Replaced torn up vinyl hose between O1 box and filter box with new aluminum ducting. Wed Mar 9 18:02:12 GMT 1994: Filemark-Calibration Wed Mar 9 19:02:22 GMT 1994: Filemark-Calibration COMMENT: Wed Mar 9 19:06:00 GMT 1994 Hardy Tsutsumi of DEC will be arriving shortly to repair RL02 unit 1, which doesn't load. Will possibly shut-down MKIII while work` is being done. DPMON COMMENT: Wed Mar 9 19:08:47 GMT 1994 Stopping dpmon to reset Daystar temp to 8.7, which looked good the other day to compare with 8.3. Wed Mar 9 19:10:04 GMT 1994: Patrol End Wed Mar 9 19:12:09 GMT 1994: Patrol Start Wed Mar 9 20:01:16 GMT 1994: Filemark-Calibration Wed Mar 9 20:09:04 GMT 1994: Patrol End DPMON COMMENT: Wed Mar 9 20:17:12 GMT 1994 Changed ProgramDefs back to disc exposure of 27. Will set Daystar` temp from 8.7 to 5.0 and sequence thru that temperature range to look for best contrast. Wed Mar 9 20:22:21 GMT 1994: Patrol Start DPMON COMMENT: Wed Mar 9 20:30:01 GMT 1994 Contrast looks much better at Daystar temp set at 5.0 Wed Mar 9 20:46:00 GMT 1994: Patrol End DPMON COMMENT: Wed Mar 9 20:48:11 GMT 1994 Increasing Daystar temp from 5.0 to 5.1 Wed Mar 9 20:49:01 GMT 1994: Patrol Start MKIII COMMENT: Wed Mar 9 20:58:39 GMT 1994 Touching up occulter stem position by rotating bench. Wed Mar 9 21:02:24 GMT 1994: Filemark-Calibration DPMON COMMENT: Wed Mar 9 21:09:45 GMT 1994 Bench was about +2 degrees off. Stem looks better situated now. MKIII COMMENT: Wed Mar 9 21:10:55 GMT 1994 RL02 repair was done off-line. Did not have to stop MKIII. Load switch on front panel had worn out. It was replaced. Interlock switch for cover was also adjusted, that was a bbit flaky too. MKIII COMMENT: Wed Mar 9 21:54:19 GMT 1994 Tried pulling out south O1 guider photocell, (the micarta part only, not the lens assembly) to see if I could get rid of the N/S intensity gradient. Used 15 MAGNIFY, ILOOK for diagnostic. I didn't see any change. Reset to 80 MAGNIFY, QLOOK. Will try moving entire assembly nest time. DPMON COMMENT: Wed Mar 9 21:58:17 GMT 1994 No appreciable difference between Daystar temp of 5.0 and 5.1 Will leave temp set at 5.1. Test to continue tomorrow. Wed Mar 9 22:02:11 GMT 1994: Filemark-Calibration Wed Mar 9 22:04:08 GMT 1994: Patrol End COMMENT: Wed Mar 9 22:04:41 GMT 1994 Ending day's observation. Activity Report: QP: 90; 222-228; 265-275; No coronal activity Tapes: MKIII: H00717 DPMON: P00017 LOW-L: L00009 Wed Mar 9 22:07:08 GMT 1994: Filemark SCAN-LOG SCAN-LOG 17:33:33. 3/9/94 DOY 68 17:42:44 17:45:58 17:49:09 17:52:21 17:55:33 17:58:46 18:01:57 18:05:11 18:08:23 18:11:37 18:14:49 18:18:04 18:21:18 18:24:30 18:27:41 1833 0 CL 18:38:50 1845 15CL 18:53:59 18:57:10 19:00:21 19:03:33 19:06:45 19:09:55 19:13:07 19:16:17 19:19:28 19:22:38 19:25:50 19:29:00 19:32:11 19:35:20 19:38:31 19:41:41 19:44:52 19:48:01 19:51:17 19:54:26 19:57:35 20:00:43 20:03:53 20:07:02 20:10:11 20:13:19 20:16:28 20:19:36 20:22:45 20:25:53 20:29:02 20:32:09 20:35:17 20:38:24 20:41:32 20:44:41 20:47:56 20:51:04 20:54:17 20:57:25 21:00:34 21:03:41 21:06:49 21:09:56 21:13:05 21:16:12 21:19:20 21:22:27 21:25:36 21:28:43 21:31:51 21:34:59 21:38:09 21:41:18 21:44:33 21:47:40 21:50:50 21:53:57 21:57:06 22:00:14 0 ERRORS OK